התראת חריגות ניטור בתאריך 17/12/2019

Monitoring Stations Avaliability:
StationRelevant Monitored PollutantsWind MeasurementBenzene MeasurementMap LocationHeightLeviathan Distance (KM)Leviathan Direction To Station
Igud – Caesarea StationBenzen, PM10, PM2.5, EthylB, TOLUENE, O3, No2, Nox0% (Dysfunctional)100% (Good)Zoom-In2012.9North-West
Igud – Maayan Zvi StationBenzen, SO2, NO2, NOX, PM2.5, O3, Toluen, Ethylb, O-Xyle97% (Good)100% (Good)Zoom-In10612.9West
Noble – Maayan Zvi StationBenzen, O3, No2, Nox, EthylB, TOLUENE0% (Dysfunctional)100% (Good)Zoom-In10612.9West
Igud – Nahsholim StationBenzen, SO2, NO2, NOX, PM2.5, O3, Toluen, Ethylb, O-Xyle97% (Good)100% (Good)Zoom-In10611.4West
Noble – Dor StationBenzen, O3, No2, Nox, EthylB, TOLUENE0% (Dysfunctional)100% (Good)Zoom-In1610.8West
MoEP – Mobile Zichron StationBenzen, SO2, O3, PM2.5, PM10, No2, Nox0% (Dysfunctional)0% (Dysfunctional)Mobile  West

Pollutants Averages Compared To Legal Values:

 BenzeneBenzeneBenzeneToluenEthylbOXyleNOXNOXNO2PM2.5PM2.5PM10PM10O3O3SO2SO2
Legal LimitNone1.2None1000NoneNone500298106None37.5None130None7113419
Time PeriodHourlyDailyMaxDailyDailyDailyHalf HourlyDailyHourlyHourlyDailyHourlyDailyHourly8-HourlyHourlyDaily
Igud – Caesarea Station0.360.300.400.780.10 14.2411.3611.3820.5219.0547.6144.789.405.85  
Igud – Maayan Zvi Station0.190.190.200.230.060.086.005.315.7121.5721.060.080.0831.6731.420.740.67
Noble – Maayan Zvi Station0.360.340.370.370.02 7.436.456.07    36.7836.51  
Igud – Nahsholim Station0.270.270.280.620.080.1633.3323.3222.7830.8127.150.160.1610.607.030.650.59
Noble – Dor Station0.130.120.140.180.02 17.0715.5913.17    7.046.26  
MoEP – Mobile Zichron Station 0.000.00     0.5024.2714.27  26.0523.581.571.39

Pollution Event Alerts Detected:

StationPollutantMeasured ValueLegal LimitWindDirectionVerbal DirectionHour Of DayNOXNO2SO2PM2.5PM10O3ToluenEthylbXyle
Igud – Nahsholim StationPM2.528.537.5144.0 (Measured)South-East00:55:00     
Igud – Nahsholim StationPM2.532.937.5135.0 (Measured)South-East01:00:00     
Igud – Nahsholim StationPM2.536.437.5126.0 (Measured)South-East01:05:00     
Igud – Nahsholim StationPM2.537.337.5131.0 (Measured)South-East01:10:00     
Igud – Nahsholim StationPM2.533.237.5127.0 (Measured)South-East01:15:00     
Igud – Nahsholim StationPM2.528.837.5115.0 (Measured)South-East01:20:00     
Igud – Nahsholim StationPM2.529.037.5120.0 (Measured)South-East01:25:00     
Igud – Nahsholim StationPM2.530.237.5130.0 (Measured)South-East01:30:00     
Igud – Nahsholim StationPM2.530.637.5130.0 (Measured)South-East01:35:00     
Igud – Nahsholim StationPM2.530.037.5126.0 (Measured)South-East01:40:00     
Igud – Nahsholim StationPM2.528.737.5120.0 (Measured)South-East01:45:00     
Igud – Nahsholim StationPM2.530.337.5104.0 (Measured)East02:05:00     
Igud – Nahsholim StationPM2.529.937.598.0 (Measured)East02:10:00     
MoEP – Mobile Zichron StationPM2.531.237.5173.0 (*Simulated*)South01:55:00     
MoEP – Mobile Zichron StationPM2.536.337.5158.5 (*Simulated*)South02:00:00     
MoEP – Mobile Zichron StationPM2.536.137.5147.0 (*Simulated*)South-East02:05:00     
MoEP – Mobile Zichron StationPM2.533.937.5148.5 (*Simulated*)South-East02:10:00     
MoEP – Mobile Zichron StationPM2.529.837.5149.5 (*Simulated*)South-East02:15:00     

 

Monitoring Gaps Alerts Detected:

StationStart TimeEnd TimeTotal Unmonitored Time
MoEP – Mobile Zichron Station00:05:0002:45:002:40:00

 

Notes:

  • This report integrates and calculates monitoring data from both the Israeli MoEP and Igud Arim Sharon-Carmel monitoring sites
  • 'Clean Air Law' legal Air value max limits can be found here
    • Benzene Israeli Max allowed 24-Hours Average limit is 1.2 PPB
  • For each monitoring station, Avaliability grade is calculated, as well as daily average and maximum Benzene level
    • On properly operated stations, measurements should be conducted once per 5 minutes, producing high Avaliability grade
    • Stations that do not monitor for more than 1-Hour will produce a Monitoring Gap Alert, For more than 4-Hours a broadcast email would be sent
  • Each Pollutant 5-Minutes measurements >= 75% Of lowest time resolution legal-limit will be shown as a Pollution Event Alert (Even though Israel legal standard might refer to daily average)
    • Pollution Event Alerts are meant to give an early warning in order to prevent violations of the daily legal limit – Not to wait for a full day of violations to occur before alerting the public
    • Alerts are defined for the following monitored pollutants (Bound to station limitations): Benzen, Toluen, PM2.5, PM10, NOX, NO2, SO2, O3
    • For each alerted pollutant, full-day graph will be generated (With legal limit marked as red line) and a broadcast email would be sent
    • For each Benzen alert, All other pollutants at the time of alert are also dispalyed, including pollutants direction trend (↗ ↘ Arrows calculated comparing current pollutant value to it's running average)
  • For Benzen, Full-day graphs will always be generated (Even without alert), since as a worst-case BTEX indicator pollutant we would like be aware of even partial unusual increase
  • Verbal description of the Pollutants Source Direction is calculated from wind data for each alert
    • Stations without wind measurements, Receive simulated average wind direction of nearby stations
    • Leviathan's direction to each monitoring station is displayed and can be compared to alerts directions